RT Version 9.1.4
Improvements
-
Disallowed forward slash and backslash in various name input fields
Bug Fixes
-
Fixed a bug that triggered a “Runtime error” on some Windows computers
-
Fixed a bug where the Skin selection from saved configurations was being ignored
-
Fixed a bug where Traces captured through the Client Window had the wrong name
-
Fixed a bug where some captured average traces showed 0.00 dB in the cursor readout despite having valid Magnitude data
RT Version 9.1.3
Bug Fix
-
Fixed a bug where plots did not respond to navigational hotkeys (arrow keys)
RT Version 9.1.2
Bug Fixes
-
SyncSource TF - changing the measurement Stimulus type from “Synchronized” to “Random" now switches the Generator noise stimulus back to “Random”
-
Fixed a bug where unchecking "Always Calculate" (LIR) in TF Measurement Settings prevented the LIR from calculating at all
-
Fixed a bug where FTW was not applying to the Phase trace
-
Fixed various issues related to measurement Weighting controls
-
Fixed a crash that occurred when normalizing a captured TF average trace with a normal TF trace
RT Version 9.1.1
Improvements
-
Increased default API command timeout to prevent erroneous timeout responses
-
Pressing the ‘G’ hotkey when the Generator is not configured now displays the message saying that the Generator is not configured
-
“Save As” is now enabled when multiple traces are selected in the Data Library
Bug Fixes
-
Fixed a bug where clicking full screen button (+) in the macOS build would not make the program exit full screen mode
-
Fixed a bug where modifying or averaging a captured Spectrum average trace would corrupt the data
-
Fixed a bug where hiding and showing a captured Spectrum average trace would cause the data to change
-
Fixed a bug where the Plot Calibrated Level setting wouldn’t immediately apply to running Spectrum measurements
-
Fixed a bug where creating a new session folder would make shown traces disappear from the Data Bar until the Data Library was refreshed
-
Fixed a bug where clicking the "Metric" radio button in General Preferences more than once would cause a black hole
-
Fixed a bug where some Y axis unit labels were missing from the RTA when "Plot Calibrated Levels" was enabled for the first time
-
Fixed a crash that occurred after “0” was manually entered into the Signal Generator level field
-
Fixed a bug where the LIR cursor readout was incorrect if the cursor was to the left of center
-
Fixed a crash that occurred when closing a secondary window and choosing to keep the tabs
RT Version 9.1
New Features
-
New Audient® EVO device control integration
-
New “SyncSource™ TF” measurement mode
-
New generator “Fade-In” option
-
Added unweighted "Peak" as a built-in sound level metric
-
Added an option to turn off zero-padding for Pink Sweeps
Improvements
-
Transfer Function - both Polar- and Complex-averaged magnitude data sets are now always calculated/stored
-
Improved behavior when multi-selecting measurements to create a live average
-
Improved visual performance while resizing the application window
-
When editing output Trim, pressing the Enter key now moves focus to the next Trim cell
Bug Fixes
-
Fixed a bug where Spectrum Target Curves were not changing level when the Banding changed
-
Fixed a bug where the visibility state of the Input Meters window was not persistent in the Windows build
-
Fixed a bug where the Signal Generator level field allowed non-integers to be entered
-
Fixed a bug where traces could no longer be assigned to a specific plot via drag-and-drop
-
Fixed a bug where enabling “Plot Proportional Graphs” would break other visible TF plots
-
Fixed a bug where the plot axis was incorrectly labeled when “Phase as Group Delay” was enabled
-
Fixed a bug where custom window names did not persist after restarting Smaart
-
Fixed a bug where the LIR axis time delay time label would be truncated if the delay time was >100ms
-
Fixed a bug where Copy/Export to ASCII was not using the banded or smoothed data set
-
Fixed a bug where the Client Window LIR plot wasn’t painting the trace correctly
-
Fixed a bug where pressing hotkeys repeatedly would open multiple copies of various dialogs
-
Fixed a bug where clicking outside of the plot type droplist would still open it
-
Fixed various bugs related to Locked Cursors, and Cursor Readout
-
Fixed various bugs related to user-defined Plot Views, and Plot Preference
RT Version 9.0.3
Bug Fixes
-
Fixed a memory leak in the macOS build.
-
Fixed various issues related to moving Smaart between screens with different DPI settings
-
Improved a rendering behavior when resizing the application window
-
Fixed a bug where Target Curves were not reacting to changes in banding.
-
Fixed a bug where recapturing a stored trace didn’t update the trace in other windows.
-
Fixed a bug where dragging a measurement engine too high in the Control Bar would make it disappear.
-
Fixed a bug where the circular delay tracker button wouldn’t always turn red when locked “on”
-
Fixed a bug where the Input Meters would not remain showing after restarting Smaart in Windows.
-
Fixed blurry Find/Track/+/- Delay buttons in the Control Bar.
RT Version 9.0.2
New Features
-
New v9 API SDK available
GUI Enhancements
-
Plot zoom states and threshold widget positions are now persistent.
Bug Fixes
-
Fixed a bug where Target Curve line thickness wouldn’t apply
-
Fixed various bugs that resulted in TF traces plotting without smoothing despite smoothing being applied.
-
Fixed a bug that resulted in the magnitude column of ASCII imports showing 0.00dB for all frequencies.
-
Fixed a crash that occurred when averaging two traces that were captured from live averages.
-
Fixed a bug where the built in SPL Meter’s input selection wasnt persistent between application launches
-
Fixed various crashes and bugs in the client window and API.
RT Version 9.0.1
GUI Improvements
-
Background dimming component is now closed if the skin manager is called into focus.
Under The Hood
-
Reimplemented Multi-Spectrum view [0] hotkey.
Bug Fixes
-
Fixed a crash that occured after changing target curve color and restarting Smaart
-
Fixed a bug where open folders outside of the session folder would collapse when the plot view was changed
-
Fixed a bug that prevented changing the TF device/channel after the TF was created
-
Fixed a bug that prevented captured TF average traces from being shown after they were hidden.
-
Fixed various issues related to showing target curves
-
Fixed tab droplist in view flyup
-
Fixed FTW cutoff indicator line